SAVE TIME. SAVE MONEY. SAVE LIVES.
MULTI-ZONE CONTROL PANELS
Our control panels employ up to 20 Brasch TRA remote transmitters (available in Carbon Monoxide and Nitrogen Dioxide) to simultaneously monitor and control a maximum of 6 zones.
IMPORTANT NOTE: A GDCP-A control panel cannot function without receiving input from a TRA transmitter.
SELECTION EXAMPLE

GDCP-A NEW
$1,680.00 each
Control Panel for operation of up to twenty (20) single gas transmitters. The transmitters are powered by the panel and are daisy-chained together.
Description
Control Panel for operation of up to twenty (20) single gas transmitters. The transmitters are powered by the panel and are daisy-chained together.
Maximum Number of Sensor Transmitters Allowed | 20 |
Maximum Number of Ventilation Systems Controlled | 6 |
Supply Voltage Required (to the panel) | 120 volt |
GSE-CM-TRA NEW
$451.00 each
Carbon Monoxide transmitter for use only with the GDCP-A Control Panel
Supply Voltage (supplied by panel): 24
Description
Carbon Monoxide transmitter for use only with the GDCP-A Control Panel
Sensor Number 1 Type | Electrochemical |
Sensor Number 2 Type | – |
Detected Gas Number 1 | CO |
Detected Gas Number 2 | – |
Usage | Use only with GDCP-A Digital Control Panels |
Supply Voltage (supplied by panel) | 24 volt |
Additional information
Number of Sensors | 1 |
---|---|
Sensor Gas | CO |
Input Voltage | 24 |
GSE-ND-TRA NEW
$451.00 each
Nitrogen Dioxide transmitter for use only with the GDCP-A Control Panel
Supply Voltage (supplied by panel): 24
Description
Nitrogen Dioxide transmitter for use only with the GDCP-A Control Panel
Sensor Number 1 Type | Electrochemical |
Sensor Number 2 Type | – |
Detected Gas Number 1 | NO2 |
Detected Gas Number 2 | – |
Usage | Use only with GDCP-A Digital Control Panels |
Supply Voltage (supplied by panel) | 24 volt |
Additional information
Number of Sensors | 1 |
---|---|
Sensor Gas | NO2 |
Input Voltage | 24 |
GDCP-A REPLACEMENT
$1,680.00 each
Control Panel for operation of up to twenty (20) single gas transmitters. The transmitters are powered by the panel and are daisy-chained together.
Description
Control Panel for operation of up to twenty (20) single gas transmitters. The transmitters are powered by the panel and are daisy-chained together.
Maximum Number of Sensor Transmitters Allowed | 20 |
Maximum Number of Ventilation Systems Controlled | 6 |
Supply Voltage Required (to the panel) | 120 volt |
GSE-CM-TRA REPLACEMENT
$451.00 each
Carbon Monoxide transmitter for use only with the GDCP-A Control Panel
Supply Voltage (supplied by panel): 24
For Volume Pricing please contact us directly.
Serial Number of your CURRENT TRANSMITTER REQUIRED for this product. Please type your Serial Number in the field on the Checkout page.
Description
Carbon Monoxide transmitter for use only with the GDCP-A Control Panel
Sensor Number 1 Type | Electrochemical |
Sensor Number 2 Type | – |
Detected Gas Number 1 | CO |
Detected Gas Number 2 | – |
Usage | Use only with GDCP-A Digital Control Panels |
Supply Voltage (supplied by panel) | 24 volt |
Additional information
Number of Sensors | 1 |
---|---|
Sensor Gas | CO |
Input Voltage | 24 |
GSE-ND-TRA REPLACEMENT
$451.00 each
Nitrogen Dioxide transmitter for use only with the GDCP-A Control Panel
Supply Voltage (supplied by panel): 24
For Volume Pricing please contact us directly.
Serial Number of your CURRENT TRANSMITTER REQUIRED for this product. Please type your Serial Number in the field on the Checkout page.
Description
Nitrogen Dioxide transmitter for use only with the GDCP-A Control Panel
Sensor Number 1 Type | Electrochemical |
Sensor Number 2 Type | – |
Detected Gas Number 1 | NO2 |
Detected Gas Number 2 | – |
Usage | Use only with GDCP-A Digital Control Panels |
Supply Voltage (supplied by panel) | 24 volt |
Additional information
Number of Sensors | 1 |
---|---|
Sensor Gas | NO2 |
Input Voltage | 24 |